Physical & Electrical Properties of Standoff Insulators
 

INSULATOR SERIES
1641 2710 2781 3061 5405 5420 5612
Tensile Strength (lbs) 2,500 7,000 3,500 1,800 6,500 6,500 1,000
Cantilever Strength (lbs) 2,000 10,000 1,500 800 2,000 1,500 675
Height Tolerance (in) ±0.015 ±0.015 ±0.015 ±0.015 ±0.015 ±0.015 ±0.015
Voltage Rating (V) * 2,500 3,400-5,500 3,200-5,000 600-2,700 5,000 15,000 600
Arc Resistance (sec) 180+ 195+ 180+ 180+ 180+ 180+ 180+
Tracking Index (V) 500+ 500+ 500+ 500+ 500+ 500+ 500+
Creep Distance (in) ** 3.250 H+0.500 H + 0.313 H + 0.250 4.000 7.000 H
Basic Impulse Level (V) N/A N/A N/A N/A 60,000 90,000 N/A
Dielec. Strength, ST (V) 20,000 20,000 20,000 18,000 20,000 20,000 5,000
Water Absorption (%) 0.14 0.14 0.14 0.14 0.14 0.14 0.14
UL Flame Resistance 94 V-0 94 V-0 94 V-0 94 V-0 94 V-0 94 V-0 94 V-0
* Voltage rating increases with insulator height

** H = insulator height

NOTE: This technical data is believed to be reliable. However, data is not to be construed as a warranty or representation for which Penn Compression assumes legal responsibility. Users should perform sufficient verification and testing to determine suitability for their own specific use. 2/24/97 Rev. 1
 

 

North Carolina
Penn Compression Moulding, Inc.
309 Components Drive
Smithfield, NC 27577
Phone:  919-934-5144   /   Fax:  919-934-1991
PennNC@PennCompression.com
Pennsylvania
Penn Compression Moulding, Inc.
540 Pacific Street
Irwin, PA 15642
Phone:  724-863-6400   /   Fax 724-863-8400
PennPA@PennCompression.com
 
  Copyright © 2008 - Penn Compression Moulding, Inc.